Home/Resources/Failed slip test

Failed a slip resistance test? What to do next.

A failed report identifies locations that need attention. Premrest can review a report from any testing provider, assess the floor and scope a suitable fix, followed by retesting.

By the team at Premrest · Updated

Start with the affected locations and the conditions recorded in the report. A low result does not, by itself, tell you whether the answer is better cleaning, a treatment, restoration or replacement. The next decision is to establish why the floor fell short and what performance is appropriate for its use.

You can request a rectification assessment from Premrest even when another company carried out the original test. Keep the complete report available so the assessment starts with the existing evidence.

1. Check what the report actually measured

Read each test location against its recorded method, conditions, result and nominated target. Check that the location names or marked plan match the areas people use. Wet and dry tests describe different conditions; a result from one location should not be assumed to cover every floor in the building.

If the report labels an area as failed, ask the original assessor to explain the comparison and the basis for the target. Keep any clarification with the report. Do not select a coating simply because its brochure advertises a higher rating.

2. Manage the affected locations while arranging assessment

Follow your site hazard-management process and involve the person responsible for safety and access. Identify the affected routes, wet areas and operational constraints so appropriate interim controls can be considered while you arrange assessment.

An enquiry or treatment booking does not establish that an area is safe to use. Record the actions taken and communicate the arrangements to the people who manage the site. If an incident, insurer or handover deadline is involved, include that context in the brief.

3. Send the existing report to Premrest

Email the report to [email protected], or use the enquiry form below to start the conversation. The form does not accept attachments; email the report separately and include the same site address so the team can match it to your enquiry.

Include the site address and city, the complete report, marked test locations or photos, the floor material if known, approximate affected area, cleaning products and methods, operating hours and any deadline. Note previous coatings or treatments and whether the floor is slippery when wet, dry or contaminated.

Premrest assesses commercial sites in Melbourne, Sydney and Brisbane and scopes national portfolio work by location. Access, availability and the assessment required are confirmed before booking. Bringing a report from another provider does not commit you to buying another test.

4. Find the cause before choosing a treatment

Grease, detergent film and embedded dirt can mask surface texture. Wear, polishing, existing coatings and the underlying material can also affect performance. Premrest reviews these factors alongside the way the area is used and cleaned.

A site assessment or further baseline testing may be needed where the report or photographs do not answer those questions. A small trial can help assess compatibility, appearance and grip before treating a wider area. Agree what will be assessed and recorded before work starts.

5. Match the work to the floor

Deep cleaning may be enough where contamination is the cause. Compatible coatings can add grip; suitable tile treatments change surface texture. Stone restoration may be appropriate for some worn surfaces. Etching is not suitable for every material and may affect appearance, especially on polished or acid-sensitive stone.

Preparation, finish, cleaning needs and drying or curing time all belong in the scope. Replacement may be appropriate where the substrate or damage makes treatment unsuitable. Read about anti-slip treatments and floor rectification before choosing a product.

The 80 Collins Street granite case study illustrates restoration followed by testing. The ANZ Melbourne coating project illustrates a different approach. Neither establishes the result another floor will achieve.

6. Retest the treated locations and plan maintenance

Agree how the work will be checked and which locations will be retested. Keep the post-treatment report with the original findings, the work scope and cleaning instructions, so the result can be traced to the area treated.

AS 4663 concerns testing existing pedestrian surfaces; AS 4586 concerns classification of new pedestrian surface materials. HB 198 provides guidance for specifying and testing slip resistance. Confirm the relevant method and assessment criteria with the assessor; one P rating is not a universal target for every location.

A result records performance under the test conditions at that time. Ongoing traffic, contamination and changes to cleaning can affect the floor later. Agree suitable maintenance and review arrangements. See slip testing and reporting and our commercial slip-rating guide.

Send us the report and site details.

Start with the enquiry below, then email your existing report to [email protected]. We confirm the assessment, scope and availability before work is booked.

Prefer to talk?
Call 1300 207 915 · Text 0480 855 665
[email protected]

* Required. Email reports separately; this form does not accept attachments. We’ll only use your details to respond to this enquiry. See our privacy policy.

Common questions

Can you help if another provider tested our floors?

Yes. Premrest can review the report, assess the affected locations and scope suitable rectification. We explain any need for further assessment or testing before agreeing the work.

Does a failed result mean the floor must be replaced?

Not necessarily. Cleaning, a compatible treatment or restoration may be suitable. The material, condition and cause of the low result determine the options.

Can you guarantee a particular slip rating?

A product rating alone cannot establish the result on your floor. Preparation, material, treatment and conditions matter. Post-treatment testing records the installed surface performance.

What affects the quote and timing?

The affected area, material, preparation, treatment, testing scope, access and curing time all matter. Send the report and site details so Premrest can scope the work and confirm availability.

A failed report is the starting point. Let’s assess the floor.